No. Soffit vents are the intake for attic ventilation, and insulation pushed into them blocks the airflow the attic depends on. Baffles, rigid channels installed at the eaves, keep the path open while letting insulation run full depth right up to the edge.
Air enters low at the soffit vents under the eaves, travels up beneath the roof deck, and exits high through ridge or gable vents. That flow carries heat and moisture out of the attic. Block the intake and the whole system stalls, the exhaust vents have nothing to draw from.
A baffle, sometimes called a rafter vent or insulation stop, is a rigid channel stapled between rafters at the eave. It holds a clear air path from the soffit up into the attic while insulation is installed to full depth right up against it. It's an inexpensive component, and its absence is one of the most common findings in older attics and in retrofits where blown-in was added without them.
From inside the attic with a light, look along the edges where the roof meets the exterior wall. You should see either daylight or a clear channel at each rafter bay. If insulation is packed into the eave with no baffle, the vents below it are doing nothing. From outside, confirm the soffit vents themselves aren't painted over, that happens more than you'd expect.
Yes. It’s a common retrofit and usually done as part of an insulation service.
Some designs ventilate differently. The important thing is that a working intake-to-exhaust path exists, whatever form it takes.