Sometimes. You may see growth at a register or just inside the duct behind it, but most HVAC mold grows where the moisture is, at the evaporator coil, in the drain pan and in the plenum, all out of view. A visual check at the register can confirm a problem but can't rule one out.
Turn the system off. Remove a register cover, usually two screws, and look inside with a flashlight, along with the register itself and the first stretch of duct you can see. You're looking for patchy dark growth that stains the surface rather than sitting loosely on it, any fuzzy texture, and any sign of dampness. Check a few registers in different rooms, and check the return grille.
Mold needs water, and the wettest part of your system is the coil, deep inside the air handler where no homeowner is looking. A clean-looking register with a musty smell at the vents is a completely normal picture for a system with growth at the coil. Absence of visible mold at the register is not evidence of absence.
A camera inspection of the duct run plus a look at the coil, drain pan and plenum. That's the combination that covers where growth actually occurs. If someone declares mold from the doorway without inspecting, or produces stock photos rather than footage of your system, treat the diagnosis as a sales step, that sequence is a known pattern.
Dark buildup at a register is more often dust, soot from candles, or fiberglass fibers from deteriorating duct liner than it is mold. The distinguishing test is moisture, if there's no plausible water source anywhere near, you're almost certainly looking at something else.
Yes, with the system off. Don’t reach into the duct or disturb anything you find, that releases spores.
Photograph it, leave it undisturbed, and have the system inspected. Identifying the moisture source matters more than identifying the species.