Usually not, and installing one incorrectly causes problems. Vapor barrier practice is climate-specific: cold climates put one on the interior side to stop indoor moisture entering the assembly. In hot-humid Central Texas, moisture drive runs the other way for much of the year, and a ceiling vapor barrier can trap moisture instead.
A vapor barrier stops moisture moving through an assembly. Which side it belongs on depends on which direction moisture is being driven, and that's a function of climate. In a cold climate, warm humid indoor air pushes outward all winter, so the barrier goes on the interior side. In a hot-humid climate running air conditioning for most of the year, the drive is frequently inward. A detail copied from northern practice can be actively wrong here.
The failure mode is trapping. Put a barrier where the assembly needs to dry, and any moisture that gets in, from a roof leak, from a humid stretch, from a bathroom fan venting into the attic, has no way out. It accumulates against the barrier, and moisture that can't dry becomes mold on the framing and decking.
Kraft-faced batts have a paper facing that acts as a vapor retarder. They're widely stocked and easy to buy without thinking about it. If you're topping up an attic here, unfaced material is generally the appropriate choice, and adding faced batts on top of existing insulation creates a retarder in the middle of the assembly, which is the worst place for one. Confirm your installer's plan rather than assuming.
Yes. Closed-cell foam is itself a vapor retarder and changes the assembly, which is why foam attics are designed differently. Follow the system’s specification.
Local code and an installer familiar with this climate. The general point is that northern-climate detailing shouldn’t be applied here by default.